Getting Started with Zephyr

From unboxing to first procedure in minutes. Zephyr is designed for zero learning curve — if you can use a traditional suction device, you can use Zephyr.

Everything you need to get started

Zephyr Device

The main suction unit -- lightweight, ergonomic, ready to use

Single-Use Sterile Tip Packs

Individually sealed, fully sterilised tips. No autoclave required -- open, use, dispose.

Power Supply

Standard UK mains adapter

Quick Reference Card

At-a-glance operating guide for your treatment room

Ready in under 2 minutes

1

Connect and Power On

  • Plug in the power supply
  • Press the power button
  • Zephyr initialises silently -- no startup burst of noise
2

Attach the Tip

  • Select the appropriate sterile tip pack
  • Open the sealed pack
  • Attach the tip to the handpiece -- it clicks into place
3

Begin the Procedure

  • Use the fingertip control to adjust airflow
  • Start suction -- Zephyr is 16× quieter than traditional devices
  • Anti-block technology maintains consistent suction throughout

What you'll notice on your first procedure

It's quiet

Dramatically quieter than any device you've used before. 16× quieter than traditional devices, you can hold a normal conversation during the procedure. Silent when idle.

No startup shock

Traditional devices blast noise when powered on. Zephyr starts gently -- 43.5 dB quieter at startup. Your patients won't flinch.

Fingertip precision

Instead of fixed or pedal-controlled suction, Zephyr gives you proportional fingertip airflow control. More control, less risk of caloric vertigo.

No blockages

Anti-block technology means you won't need to stop, clear the tip, and restart. Suction stays consistent even with fine debris.

Single-use sterile tips

No cleaning, no autoclaving, no cross-contamination risk. Open a new pack for each patient. Dispose after use.

Getting the most from Zephyr

Start with routine cases

For your first few procedures, choose straightforward ear wax cases. This lets you get comfortable with the fingertip control in a low-pressure setting.

Let patients notice the difference

Many clinicians report that patients spontaneously comment on how quiet the procedure was. This is a natural opening to mention your investment in their comfort.

Track your procedure times

Most clinicians see a 2-3 minute reduction per procedure within the first week. Over a full day, this translates to additional appointment capacity.

Reorder tips early

Single-use tips are your only ongoing consumable. Set up a reorder schedule based on your procedure volume so you never run short.

Zephyr at a glance

Specification Detail
Operating Noise Level ≤75 dB
Idle Noise Level 0 dB (silent)
Overall Noise Reduction 24.9 dB quieter (16x lower SPL)
Suction Control Proportional fingertip airflow
Anti-Block Technology Patented
Tips Single-use, fully sterile
Regulatory CE Mark / UKCA, Class II, ISO 13485
ENT UK 2024 Fully compliant
Training Required None -- plug and play

Need help?

Our team is available to support you through setup and your first procedures. Contact us at info@spokemedical.com or speak to your distributor.

Ready to see Zephyr in your clinic?

Discover how Zephyr is redefining ear care with the first innovation in microsuction technology in over 75 years.

Contact Us